WILBERT

Wildauer Bücher+E-Medien Recherche-Tool

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    Electronic Resource
    Electronic Resource
    Springer
    Chromatographia 35 (1993), S. 149-152 
    ISSN: 1612-1112
    Keywords: Thin-layer chromatography ; Mobile phase optimization ; Microcomputer ; Simplex optimization
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary A computer-assisted mixture design simplex method is presented for optimization of the separation of a mixture of five benzoic acid derivatives in reversephase HPTLC and twelve PTH-amino acids in normal phase HPTLC. A two-factor selectivity rectangle concept was used. The method is based on a special polynomial estimated from nine experimental runs, using the RF difference as the selection criterion, with connection to a general simplex method for optimization using a microcomputer. Excellent agreement is obtained between predicted data and experimental results, and more than half the number of experiments required in the general simplex method can be omitted.
    Type of Medium: Electronic Resource
    Location Call Number Limitation Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    Springer
    Chromatographia 31 (1991), S. 143-146 
    ISSN: 1612-1112
    Keywords: Column liquid chromatography ; Molecular structure parameters ; Prediction of retention ; Phosphoroamidothiotes
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary Multi-variable regression analysis between lnkw, c (in retention equation lnk′=lnkw+cCb) and molecular structure parameters, including hydrophobicity, electric effect, field effect and position-specific effect constant, was carried out with O-ethyl, O-aryl and N-isopropyl phosphoroamidothioates as test solutes. With these quantitative relationships, the retention behaviour of these solutes for different mobile phase compositions was predicted. The results showed that there are only 26.7% of total, experimentally measured, capacity factors with relative deviations larger than 5% and only 2.2% with deviations larger than 10%, which means that it is possible to apply the method reported to predict retention values for qualitative purposes for different mobile phase compositions.
    Type of Medium: Electronic Resource
    Location Call Number Limitation Availability
    BibTip Others were also interested in ...
  • 3
    Electronic Resource
    Electronic Resource
    Springer
    Chromatographia 31 (1991), S. 173-176 
    ISSN: 1612-1112
    Keywords: Gas chromatography ; Stationary phase optimization ; Mobile phase optimization ; Column temperature optimization ; Multifactor optimization
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary A computer-assisted method is presented for the simultaneous multifactor optimization (stationary phase loading, column temperature and carrier gas flow rate) of the analytical conditions for the optimum separation of multicomponent samples in gas chromatography. The optimization of the separation over the experimental region is based on a special polynomial from twelve preliminary experiments using the resolution as the selection criterion. Computer scanning technique was used for optimum selection in three dimensions. Excellent agreement was obtained between the predicted data and the experimental results.
    Type of Medium: Electronic Resource
    Location Call Number Limitation Availability
    BibTip Others were also interested in ...
  • 4
    Electronic Resource
    Electronic Resource
    Springer
    Chromatographia 38 (1994), S. 187-190 
    ISSN: 1612-1112
    Keywords: Column liquid chromatography ; Optimal mobile phase ; Gradient elution ; Microcomputer
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary A computer-assisted method is presented for the optimization of separation in gradient elution reversed-phase HPLC. The method is based on a polynomial estimation from nine preliminary experiments according to a two-factor (initial solvent composition C and gradient time T) rectangular design. This is followed by a two-dimension computer scanning technique. Resolution is used as the selection criterion. Good agreement was obtained between predicted data and experimental results.
    Type of Medium: Electronic Resource
    Location Call Number Limitation Availability
    BibTip Others were also interested in ...
  • 5
    Electronic Resource
    Electronic Resource
    Springer
    ISSN: 1572-9559
    Source: Springer Online Journal Archives 1860-2000
    Topics: Physics
    Notes: Abstract The cyclotron autoresonance maser (CARM) is shown to be capable of extremely high power efficient operation with relatively weak magnetic field requirements. A general description of the CARM traveling wave amplifier is presented. The linear theory is applied to study the stability of the device and a self-consistent numerical simulation code is used to predict the performance. It is found that grazing intersection often gives superior performance, especially for high current electron beams. The designs of two CARM amplifiers for the applications of a high gradient rf linac and electron cyclotron resonance plasma heating as well as a proof of principle experiment are presented.
    Type of Medium: Electronic Resource
    Location Call Number Limitation Availability
    BibTip Others were also interested in ...
Close ⊗